Walter, R.J.; Uang, C.-M. (2020). "Technical Note: Unbraced Length Requirements for Steel Special Cantilever Column Systems," Engineering Journal, American Institute of Steel Construction, Vol. 57, pp. 243-245.

AISC Seismic Provisions Section E6.4b for steel special cantilever column systems (SCCS) requires clarification based on inquiries to the AISC Steel Solution Center. In the 2016 edition, it is unclear if bracing is required for all special cantilever columns or for columns with unbraced lengths that exceed the maximum beam brace spacing of Lb per Section D1.2a for moderately ductile members. Instead of using Equation D1-2, which is applicable to I-shaped beams only, equations for SCCS columns have been derived for both I-shaped members and rectangular HSS or box-shaped members. The proposed revision provides specific situations when bracing is required.

  • Published: 2020, Quarter 4

Author(s)

Robert J. Walter and Chia-Ming Uang